Lights go out. Your solar panels sit in the sun. Yet the inverter stops. This is not a bug. It is a safety feature called anti-islanding. It protects utility crews, your equipment, and the grid. Here is how it works and how to keep your home running during an outage without breaking the rules.
According to the U.S. Department of Energy, grid-tied solar equipment must comply with strict interconnection and safety practices to operate with the utility network. That includes automatic shutdown during a power outage to prevent backfeeding lines that crews may be repairing. See the overview at U.S. Department of Energy: Solar Energy.
How a Grid-Tied Inverter Decides to Stop
Synchronization with the grid
A grid-tied solar inverter locks onto the utility’s voltage and frequency. It produces AC that matches the grid waveform. This tight sync allows your solar panel system to export power safely during normal operation. If the reference disappears, the inverter must pull back.
Anti-islanding detection
“Islanding” is a pocket of energized wires left behind after the utility supply fails. It can happen if local solar keeps feeding a local section. Inverters avoid that with detection methods:
- Passive monitoring: Watch voltage, frequency, and rate-of-change for abnormal values.
- Active probing: Inject small signals to test if the grid is present. Methods include frequency and voltage shift techniques.
Modern inverters add grid support features and ride-through where codes allow, but they still must shut down if limits are exceeded. IRENA notes that advanced or “smart” inverters manage voltage and frequency support while maintaining anti-islanding protections.

Trip windows and timing
In North America, many settings follow IEEE 1547 and UL 1741 SA profiles defined by utilities. Exact values vary by region and interconnection agreement. Typical 60 Hz windows look like this:
Parameter | Typical grid-tied setting (60 Hz regions) | Maximum trip time |
---|---|---|
Under-voltage | Below ~88% of nominal (e.g., <106 V on a 120 V leg) | Up to 2 s |
Over-voltage | Above ~110% of nominal (e.g., >132 V on a 120 V leg) | Up to 1 s |
Under-frequency | Below ~59.3 Hz | ~0.16 s |
Over-frequency | Above ~60.5 Hz | ~0.16 s |
These figures are common in utility documents, but your inverter may ship with different defaults or may be programmed by the installer. Always check the interconnection approval.
Why Shutdown Is Required During a Power Outage
Safety for lineworkers and neighbors
If local solar feeds a dead line, a repair crew can face live conductors where they expect zero voltage. Anti-islanding removes that risk. DOE’s solar program materials emphasize safe interconnection practices and automatic disconnection during faults. See DOE: Solar Energy.
Equipment protection and power quality
During a blackout, local loads and solar production rarely match. Voltage can swing. Frequency can drift. Household electronics and motors do not tolerate that. Anti-islanding keeps your equipment safe.
Outage context
Outage duration varies widely by region and weather. The EIA Electric Power Annual shows that average annual outage hours per customer fluctuate year to year, with major storms pushing totals higher. Planning for backup power requires looking at local reliability data, not just a national average.
How to Keep Power Legally During a Blackout
Use a hybrid inverter with a battery and transfer switch
A hybrid (grid-interactive, battery-capable) inverter can form a local AC grid during an outage. It disconnects from the utility with an automatic transfer switch. Your “critical loads panel” stays on, powered by the battery and, if sunlight is available, the solar array.
- Meets anti-islanding rules by opening the point of common coupling.
- Keeps PV energy available behind the transfer switch.
- Works silently and indoors.
IEA’s Solar PV analysis highlights the growth of distributed PV and the role of modern inverters in grid interaction. These systems support reliability without violating safety codes.
Size the battery to your real needs
List the essential loads. Common items are a refrigerator (80–150 W average, 600–1,200 W surge), a few LED lights (5–10 W each), internet gear (10–20 W), and a gas boiler fan (60–200 W). Many homes keep essential demand near 300–800 W average.
A LiFePO4 battery is a strong choice for daily cycling and standby. It offers stable chemistry, long cycle life, and deep usable capacity. Typical values:
- Usable depth of discharge: 80–90%
- Cycle life: 4,000–6,000 cycles at 80% DoD
- High round-trip efficiency: ~95%
Quick sizing example
Assume 600 W average over 8 hours. That is 4.8 kWh. Add 20% buffer. A 6 kWh usable battery covers an evening outage. For a full day, target 10–15 kWh usable. A 5–8 kW hybrid inverter supports typical surges and a small HVAC fan. The solar array can recharge the battery the next day if the sky is clear.
Component Choices That Work Together
Integrated ESS for simplicity
An all-in-one home energy storage system combines a LiFePO4 battery, a hybrid inverter, and system controls. This cuts wiring complexity and shortens commissioning. It also improves firmware coordination for fast transfer and advanced grid support.
Off-grid-capable solar for remote sites
For cabins, farms, and locations with weak utility service, a full off-grid solar solution provides complete independence. It uses a solar inverter designed to form a stable AC bus, plus a battery bank and, if needed, a generator port for long storms.
Standalone batteries and hybrid inverters
Already have a grid-tied array? You can add a hybrid inverter and a battery to create a backup subpanel. This keeps your current panels productive during outages while meeting interconnection rules.
Backup option | Keeps PV on during outage? | Noise | Emissions | Maintenance | Typical use |
---|---|---|---|---|---|
Hybrid inverter + LiFePO4 battery | Yes (behind transfer switch) | Silent | Zero at point of use | Low | Homes, small businesses |
Standby generator (ATS) | No for PV alone; yes if paired with hybrid inverter | Loud | Combustion exhaust | Fuel, oil service | Long outages, fuel on-site |
Off-grid solar system | Yes | Silent | Zero at point of use | Moderate (battery care) | Remote sites, unreliable grids |
IRENA notes that modern inverter functions can support voltage control and ride-through in normal grid operation, while islanding protection remains in place for safety. See Innovation Landscape for a Renewable-Powered Future.
Standards and Compliance in Plain Terms
Most grid-interactive inverters in the U.S. comply with IEEE 1547 and are certified to UL 1741 (including SA profiles). Utilities may apply regional rules that fine-tune trip settings, volt-var functions, and frequency-watt behavior. You do not need to tweak these. Your installer programs the unit to the approved profile.
The International Energy Agency states that as PV grows, grid codes and inverter behavior play a larger role in stability and reliability. See IEA: Solar PV.
Field Example: Keeping a Home Running
System: 6 kW PV array, 8 kW hybrid inverter, 10 kWh LiFePO4 battery, critical loads panel with fridge, internet, lights, gas boiler, and a few outlets.
- Grid failure at 6:15 pm. Transfer switch opens in under 100 ms. Lights flicker briefly.
- Average load 550–700 W through the evening. Battery drops from 100% to 35% by 5:30 am.
- Sunrise charging begins. By noon, the battery reaches 90% while loads run. No generator used.
This setup respects anti-islanding rules and keeps essentials on. It also lowers daily bills through time-of-use shifting if your utility allows.
Practical Checklist for a Smooth Backup Install
- Define critical loads and move them to a dedicated subpanel.
- Size a LiFePO4 battery for 8–24 hours of target autonomy.
- Select a hybrid inverter with grid-forming capability, fast transfer, and the right surge rating.
- Confirm certifications (e.g., UL 1741 SA) and the utility profile required.
- Plan the PV recharging strategy and roof/string layout for daytime charging during outages.
- Get interconnection approval and an inspection. Test outage operation twice a year.
Frequently Asked Questions
Why do inverters shut down during grid failure?
To prevent islanding. The inverter must not energize lines during a power outage. This protects crews and your equipment. It is required by interconnection rules.
Can microinverters or optimizers keep my house powered?
Not by themselves. Device type does not remove anti-islanding. You need a hybrid, grid-forming inverter plus a battery and a transfer switch to create a legal local microgrid.
Do I need a generator as well?
Many homes do fine with a 10–20 kWh LiFePO4 battery for short outages. In long winter storms with limited sun, a generator port can help. Hybrid inverters can manage both sources safely.
Key Takeaways
- Inverters stop during a power outage by design. Anti-islanding protects people and equipment.
- Standards and utility rules define voltage and frequency trip limits and timing.
- To keep essentials on, use a hybrid inverter, a LiFePO4 battery, and a transfer switch feeding a critical loads panel.
- Plan sizing with real load data. Test the system regularly.
For broader context on PV growth and grid integration, see IEA: Solar PV, IRENA’s innovation report, the EIA Electric Power Annual, and DOE’s solar resources. These sources align on a simple point: safe solar interconnection includes anti-islanding, and battery-backed systems are the cleanest path to resilient power.