SoC, DoD, and cycle life relationship for a LiFePO4 battery

Plain definitions and quick math

Three metrics set expectations for LiFePO4 storage performance.

Term What it refers to Unit Quick formula Typical range (LiFePO4)
SoC State of Charge: how full the battery is % SoC + DoD = 100% 10–95% in daily use
DoD Depth of Discharge: how much is taken out % DoD = 100% − SoC 30–90% in daily use
Cycle Life Number of full cycles until End of Life (EoL) cycles EoL commonly at 70% remaining capacity 3,000–7,000+ at 80% DoD, 25°C, modest C‑rate

End of Life (EoL) is typically defined as the point where the battery retains near 70% of its original capacity. This convention is noted in Innovation Outlook: Smart charging for electric vehicles by IRENA, which also highlights the influence of DoD, temperature, and current on degradation.

Why DoD and SoC shape LiFePO4 cycle life

Chemistry drivers backed by testing

Cycle count rises as DoD falls. Shallower cycles are less stressful to the electrodes and electrolyte. According to IRENA, degradation is affected mainly by discharge current, DoD, and temperature; tests show limited added wear in use profiles that keep SoC near 60–80% for vehicle batteries, a window that also benefits stationary LiFePO4 storage in many cases (IRENA, Smart Charging).

System context: cycling patterns

PV + storage often shifts late‑afternoon peaks, which drives a daily cycle for home and small business ESS. The IEA Power System Transformation technical annexes note that batteries help address demand shifts linked to solar output ramps. Electrochemical storage responds in seconds with discharge times spanning minutes to hours, aligning well with evening peaks, as outlined in the IEA’s The Power of Transformation.

EoL convention and expectations

Most datasheets state cycle life to 70% remaining capacity at a standard test temperature. This aligns with the EoL convention in IRENA’s work on EV and storage systems (IRENA, Smart Charging). Tracking from the IEA shows rapid progress in battery storage across grid services, framing realistic deployment contexts (IEA, Energy Storage – Tracking Clean Energy Progress).

Practical settings that extend life

Use a conservative SoC window, moderate currents, and keep temperatures in check. The ranges below balance usable energy with longevity for LiFePO4 storage.

Use case Suggested SoC window Notes
Daily self‑consumption 15–90% Good balance of usable kWh and life; typical 0.5C discharge limit
Backup‑first (rare cycling) 40–60% standby; 15–95% during outages Keep mid‑SoC in standby to reduce calendar aging
EV‑style V2H/V2G 60–80% SoC bands in this range showed limited added wear in tests (IRENA)
Off‑grid seasonal 20–90% Wider band is fine if temps are controlled and currents are modest
  • Charge voltage: many LiFePO4 packs favor 3.45–3.55 V per cell (55.2–56.8 V for 16‑cell “48 V” packs) for daily use. Full 3.65 V per cell (58.4 V pack) is safe but may increase stress at high SoC. Follow the BMS and manufacturer profile.
  • Temperature: aim for 15–30°C. High temps accelerate capacity fade; very low temps reduce power and limit charge acceptance.
  • C‑rate: 0.5C continuous and 1C short bursts are common for long life. Higher currents raise internal heat and wear.
  • Storage: for long idle periods, park near 40–60% SoC in a cool, dry space.

These settings reflect general LiFePO4 behavior and align with degradation drivers discussed by IRENA. Always apply the pack’s datasheet limits.

A quick case calculation

Consider a 10 kWh LiFePO4 battery in a home ESS. Round‑trip efficiency is 94% (typical), and daily discharge is planned at 80% DoD.

  • Usable energy per day ≈ 10 kWh × 0.80 × 0.94 = 7.52 kWh
  • Cycles per year ≈ 365 if cycled once daily
  • If rated 6,000 cycles to 70% capacity at 80% DoD: 6,000 / 365 ≈ 16.4 years (field life varies with temp and C‑rate)
Parameter 50% DoD plan 80% DoD plan
Daily usable energy (94% eff.) 10 × 0.50 × 0.94 = 4.7 kWh 10 × 0.80 × 0.94 = 7.52 kWh
Typical cycle life range 6,000–10,000 cycles 3,000–7,000 cycles
Estimated years at 1 cycle/day 16–27 years 8–19 years
Total lifetime throughput 10 kWh × 0.50 × cycles 10 kWh × 0.80 × cycles

Throughput (kWh delivered over life) can be similar across different DoD plans because higher DoD provides more energy per cycle but may reduce cycle count. Local temperature and current profile often dominate outcomes.

How SoC is estimated and how to verify it

  • Coulomb counting: the BMS integrates current over time to track in/out amp‑hours. It can drift and needs periodic recalibration.
  • OCV checks: resting open‑circuit voltage correlates with SoC for LiFePO4, but the curve is flat through mid‑SoC. Combine with coulomb counting for accuracy.
  • Calibration practice: allow a full, gentle charge to the recommended absorption target, and an occasional controlled cycle through the normal window to reset the estimator. Follow the BMS instructions.
  • Data logging: review BMS logs for cycle count, min/max cell voltages, and temperature. This helps verify that the SoC window matches the plan.

Common mistakes and quick checks

  • Confusing SoC and DoD: remember DoD = 100% − SoC.
  • Living at 100% SoC: parking full for long periods raises stress. Park mid‑SoC if the battery sits.
  • Deep discharges at high current: high DoD and high C‑rate together increase heating and wear.
  • Hot enclosures: attic or sun‑exposed sheds push temperatures up; ventilation and shade make a big difference.
  • Ignoring firmware: BMS and inverter updates often improve charge control and balancing behavior.

Bringing it all together

Set a realistic SoC window, keep temperatures in range, and stay within the pack’s C‑rate limits. Size capacity so daily DoD lands near 50–80% with headroom for cloudy days or outages. These steps protect cycle life while delivering the kWh you need.

References

FAQ

What is DoD in LiFePO4 batteries?

Depth of Discharge is the percentage of capacity removed during use. If a 10 kWh pack delivers 6 kWh, the cycle DoD is 60%. SoC + DoD equals 100% at any point.

Is 100% DoD safe occasionally?

LiFePO4 can handle full cycles if the datasheet allows it, but frequent 100% DoD can reduce cycle count. Planning daily operation near 50–80% DoD usually improves longevity.

How many cycles can I expect at 80% DoD?

Many LiFePO4 packs list 3,000–7,000 cycles to about 70% remaining capacity at 25°C with modest C‑rates. Check your datasheet and temperature profile.

What SoC is best for storage longevity?

Staying near mid‑SoC during standby and using an operation window like 15–90% for daily cycling is a good start. IRENA notes limited added wear in SoC bands near 60–80% in tested use profiles.

Does partial charging harm LiFePO4?

No. Partial cycling typically helps. Avoid long periods at very high SoC and high temperature. Periodic calibration following BMS guidance keeps SoC estimation accurate.

Disclaimer: Technical information only. Non‑legal, not financial advice. Always follow product manuals and local codes.

author avatar

Anern Expert Team

With 15 years of R&D and production in China, Anern adheres to "Quality Priority, Customer Supremacy," exporting products globally to over 180 countries. We boast a 5,000sqm standardized production line, over 30 R&D patents, and all products are CE, ROHS, TUV, FCC certified.

Reading next

Understanding Solar Power Terminology
Understanding Solar Power Terminology

Leave a comment

All comments are moderated before being published.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.