LiFePO4 is known for stability and safety, yet long-term storage still bleeds energy. Some loss is chemical self-discharge; some is electronics quietly sipping power. This piece separates myth from reality, quantifies losses across storage temperature, and gives actionable steps to keep your pack healthy for months or a full off-season.

What actually discharges during storage
Chemistry vs electronics
Two mechanisms reduce state of charge (SoC) during downtime:
- Intrinsic self-discharge: side reactions inside LiFePO4 cells. It rises with temperature.
- Parasitic loads: the battery management system (BMS), meters, trackers, and standby DC devices. This loss is often larger than the chemistry itself.
Industry and laboratory data put modern LiFePO4 intrinsic self-discharge near 1.5%–3% per month at 25°C, dropping in the cold and climbing in the heat. BMS standby can range from microamps to several milliamps; over months, even 1–3 mA meaningfully adds up. Long-duration storage is tricky for batteries partly for this reason. As summarized by Innovation outlook: Thermal energy storage, batteries are highly efficient for short-term cycling but less suited for very long storage due to self-discharge and scaling requirements.
Myths vs reality
Myth 1: “LiFePO4 has near‑zero self-discharge, so full charge for a year is fine.”
Reality: At 25°C, expect roughly 1.5%–3% per month chemically, plus any BMS draw. Full storage elevates voltage stress and ages the pack. For multi-month storage, target 40%–60% SoC and a cool, dry place.
Myth 2: “Colder is always better.”
Reality: Cooler storage reduces self-discharge, but keep the pack above freezing for best results and avoid charging below 0°C without a preheat strategy. Store at 10–25°C for long intervals. Heat accelerates losses and aging; cold complicates charging.
Myth 3: “Turning the inverter off stops all drain.”
Reality: BMS and small electronics can still draw current. A 100 Ah pack with a 3 mA standby loses about 2.16 Ah per month (~2.2%). Use a true battery-side disconnect or a ship-mode feature to bring standby into the microamp range.
Myth 4: “Once low-voltage cutoff triggers, losses stop.”
Reality: Many BMSs still require micro-power to monitor state, and deep depletion risks cell imbalance or a “bricked” pack. Keep SoC in the recommended storage band and check voltage periodically.
Myth 5: “A continuous trickle is healthy.”
Reality: LiFePO4 does not need float charging. Maintain mid SoC, then top off every few months if needed. Continuous float at high voltage raises side reactions and calendar aging.
Storage temperature and self-discharge: what the data suggests
Self-discharge follows temperature. Many field results align with an Arrhenius-type trend: warmer storage increases rate. The broader energy-storage literature reinforces this relationship. For context, Projected Costs of Generating Electricity 2020 frames how losses and time affect storage value via LCOS methods, with long durations penalizing battery options partly because idle periods stack up losses and capital costs. Thermal stores, on the other hand, can hold energy with far lower long-term leakage, as noted in Solar Energy Perspectives.
Storage temperature | Typical LiFePO4 intrinsic self-discharge | Common BMS standby (illustrative) | Recommended storage SoC |
---|---|---|---|
0°C | ~0.5%–1.5% per month | 0.05–2 mA (design-dependent) | 40%–60% |
10°C | ~1%–2% per month | 0.05–2 mA | 40%–60% |
25°C | ~1.5%–3% per month | 0.1–3 mA | 40%–50% for 6–12 months |
35°C | ~2.5%–4.5% per month | 0.2–5 mA | 40%–50%, shorten intervals |
45°C | ~4%–6% per month | 0.3–5 mA+ | Not advised; cool the site |
Notes: Ranges reflect typical modern cells. Vendor data may differ. Parasitic draw scales with product design and features (BLE, telemetry, relay drivers). For very long, seasonal storage where electrical self-discharge is a showstopper, Innovation outlook: Thermal energy storage highlights thermal solutions that hold energy with minimal long-term loss, and EERE’s CSP particle-receiver work shows heat can be stored at very high temperatures, opening paths that avoid battery idle losses.
Plan long-term storage with real numbers
Step 1: Estimate total monthly loss
Total loss per month ≈ intrinsic self-discharge + BMS standby. Example at 25°C: a 100 Ah pack, 2% intrinsic plus 3 mA standby. The standby loss per month is 0.003 A × 720 h ≈ 2.16 Ah → 2.16%. Total ≈ 4.16% per month.
Step 2: Check months-to-threshold
If you store at 50% SoC and want to stay above 20% SoC, you have a 30% margin. With 4.16% losses per month, you hit 20% in roughly 7 months. Cooling the storage to 10–15°C or enabling a true disconnect to cut standby makes this much longer.
Step 3: Pick temperature and SoC
- Target 10–25°C, low humidity, dust-free. Ventilate to avoid heat build-up.
- Set SoC 40%–60% for 3–12 months. Aim near 50% if storage exceeds 6 months.
- Use hardware disconnects or ship-mode. Verify standby with a meter instead of assumptions.
Why long-duration electrical storage is hard
Long intervals favor technologies with minimal idle loss. Batteries shine at daily cycling, but for months-long storage, losses and cost stack up. Projected Costs of Generating Electricity 2020 details LCOS methods that show costs rising with duration for batteries. IRENA’s analysis adds that thermal storage options can hold energy for extended periods with low leakage, and research like the EERE particle-receiver success story highlights high-temperature heat storage advances. For solar-plus-storage planners, these insights support a mixed toolkit: LiFePO4 for short to medium intervals; thermal or pumped hydro for seasonal windows.
Practical tactics for long-term LiFePO4 storage
- Use a true battery-side disconnect. Aim for standby below 50 µA during storage.
- Store between 10–25°C. If space is hot, add passive ventilation or shade; even a 5–10°C drop can meaningfully cut losses.
- Top up only as needed. Check SoC or open-circuit voltage every 2–3 months; brief charge to return to ~50% SoC.
- Avoid full SoC or very low SoC during storage; both add stress. Keep packs balanced via a normal charge cycle before storage.
- Label storage start date and target check date. Use a simple log to prevent accidental deep storage beyond the safe window.
Worked examples
Example A: 48 V, 100 Ah rack module, 25°C, ship-mode available
Ship-mode standby: ~50 µA. Intrinsic: ~2%/month. At 50% SoC start, expected 6 months later ≈ 50% − (2% × 6) ≈ 38%. Do a quick 15–20% recharge to return near 50% and re-enter ship-mode.
Example B: 12.8 V, 100 Ah pack in a hot shed (35°C), no disconnect
Intrinsic: ~3.5%/month. BMS+BLE: ~2 mA → ~1.4%/month. Total ≈ 4.9%/month. From 60% SoC, 6 months later ≈ 60% − (4.9% × 6) ≈ 30.6%. Action: add a disconnect and reduce ambient to ~25°C to nearly halve monthly loss.
What standards and reports suggest
Energy agencies consistently point to the impact of temperature and duration on storage performance and cost. Key takeaways include: batteries suit frequent cycling and short to medium durations; long-duration applications favor low-leakage media. See Innovation outlook: Thermal energy storage for comparative efficiency and duration insights, Solar Energy Perspectives for thermo-chemical storage characteristics, and Projected Costs of Generating Electricity 2020 for LCOS context across durations.
Key takeaways you can put to work today
- At 25°C, plan around 1.5%–3%/month intrinsic self-discharge; at 35°C, use 2.5%–4.5%.
- BMS standby of 1–3 mA adds roughly 0.7%–2.2%/month on a 100 Ah pack. Eliminate it with a true disconnect.
- Store at 40%–60% SoC and 10–25°C for multi-month periods. Schedule a check every 2–3 months.
- Aim for ship-mode or microamp standby if storage exceeds 6 months.
Safety notes and disclaimer
Do not charge LiFePO4 below 0°C without approved preheating. Protect terminals from short circuits. Follow manufacturer limits for voltage and temperature. Non-legal advice: this content is for technical education and planning, not a substitute for product manuals, warranties, or safety codes.
FAQ
How long can a LiFePO4 battery sit unused at 25°C?
With 40%–60% SoC and a true disconnect, 6–12 months is reasonable. Without a disconnect, plan checks every 2–3 months and expect 2%–5% monthly losses depending on design and temperature.
What SoC is best for 12-month storage?
Start near 50% SoC, store at 10–20°C, and place the pack in ship-mode. Do a mid-year check and brief top-up if SoC drifts toward 30%–35%.
Does cell balancing matter during storage?
Balance cells with a normal charge cycle prior to storage. Passive balancers stop near full charge, so do not rely on balancing while idle. A mid-season maintenance charge helps keep cell voltages aligned.
Is a hot garage acceptable?
High heat increases self-discharge and aging. If the garage hits 35–45°C, relocate, add ventilation, or insulate to bring storage near 20–25°C. Even a modest temperature drop reduces losses. For very long storage needs, consider non-battery options highlighted by IRENA and IEA.